Trade Resources Market View List of The Major Differences Between EN 50548:2011 and DIN V VDE 0126-5

List of The Major Differences Between EN 50548:2011 and DIN V VDE 0126-5

  • Latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement.                                                         

                                                                                                                                      (dop) 2012-02-14
  • Latest date by which the national standards conflicting with the EN have to be withdrawn.  
                                                                                                                                      (dow) 2014-02-14

The major differences between EN 50548:2011 and DIN V VDE 0126-5 listed as below:

 

Clause DIN V VDE V0126-5 EN 50548:2011
1 Scope Rated voltage 1000 V 1500 V
3.26 Application class A >50V DC or 240W >120V DC
3.28 Application class C <50V DC or 240W <120V DC
4.2 Marking reverse current None With Irev
4.5 Connector VDE 0126-3 EN 50521
4.6 CablesCables shall be flexible and the conductor shall be class 5 according to EN 60228. Without such requirement With such requirement
4.14.2 Rated impulse voltage for reinforced  insulation None With (12kV for rated voltage 1000V)
5.1.2 Test specimens 16pcs 17pcs (the last one is for reverse current test)
5.2.6 Preparation for specimen of reverse current test None With (terminal for cell connection shall be short-circuit)
5.3.13 Ball pressure test.Higher temperature of insulation material near diode or current carrying part No considered Considered
5.3.16 Wet leakage current test Surface tension of solution  is considered Surface tension of solution  is not considered
5.3.16 Wet leakage current test (for connector) Connector shall be immersed during test Connector shall be thoroughly sprayed
5.3.17 Humidity-freeze-test No RH control below 25°C No RH control below 85°C
5.3.18 Bypass diode thermal test Insulation temperature is not measured Insulation temperature shall not be measured
5.3.23 Reverse current test at junction box None Reverse current for 2h under 85°C

 

Source: http://tuv-sud.cn/technical-news-download-file/items/en-50548-was-approved-by-cenelec-on-14-feb-2011.html
Contribute Copyright Policy
EN 50548 Was Approved by Cenelec on 14 Feb., 2011