On April 12, 2012, European Union published the notification of G/TBT/N/EU/34, and established ecodesign requirements for directional lamps, LED lamps and related equipments.

Each ecodesign requirement shall apply in accordance with the following stages: 

Stage 1: 1 September 2013
Stage 2: 1 September 2014
Stage 3: 1 September 2016

Notified regulation provides specific requirements for energy efficiency index (EEI) for directional lamps, functionality requirements and product information requirements.

1. EEI requirements

Application date

Maximum energy efficiency index (EEI)
Mains-voltage filament lamps Other filament lamps High-intensity discharge lamps Other lamps
Stage 1  Φ use >450lm, 1.75 Φuse≤450lm 1.2, Φ use  >450lm, 1.75 0.5 0.5
Stage 2  1.75 0.95 0.5 0.5
Stage 3  0.95 0.95 0.36 0.2


  
2. Energy efficiency requirements for lamp control  gear
From stage 2, the no-load mode input power of lamp control gear intended for use between the mains and the switch for turning the lamp load on/off shall not exceed 1.0W. From stage 3, the limit shall be 0.50 W.
For lamp control gear with output power (P) over 250W, the no-load mode input power limits shall be multiplied by P/250. As from stage 3, the standby power of lamp control gear shall not exceed 0.50 W. 
From stage 2, the efficiency of control gear that transforms mains voltage to extra-low voltage for halogen lamps shall be at least 0.91 at 100% load.

3. Functionality requirements
Notified regulation put forward all kinds of functionality requirements for directional lamps and for non-directional LED lamps and directional LED lamps. For example, it specifies the following functionality requirements for LED lamps (including non-directional and directional):

Functionality parameter

Requirement
Lamp survival factor at 6000h From stage 2: ≥0.90
Lumen Maintenance at 6000h From stage 2: ≥0.80
Number of switching cycles before failure ≥ 15000 if rated lamp life ≥ 30000hotherwise: ≥ half the rated lamp life expressed in hours
Starting time < 0.5 Sec.
Lamp warm-up time to 95% Φ < 2 Sec.
Premature failure rate ≤ 5.0% at 1000h1000h
Colour rendering (Ra) ≥80≥ 65 if the lamp is intended for outdoor or industrial applications
Colour consistency Correlated colour temperature (CCT) spread within a six-step MacAdam ellipse or less.
Lamp power factor (PF) P ≤ 2W : no requirement ; 2W < P ≤ 5W : PF > 0.4;5W < P ≤ 25W : PF > 0.5;P > 25W : PF > 0.9

4. Product information requirements
Notified regulation provides specific product information requirements for directional lamps, and provides additional product information requirements for LED lamps replacing fluorescent lamps without integrated ballast.